LMA Airways

Innovation That Protects.

Smarter designs. Broader applications. Trusted performance. Leading the way in airway management—since day one.

LMA Unique (Silicone Cuff) Airway

Connector
Standard 15 mm connector
Aperture Bars
Designed to prevent the blockage of airflow by the epiglottis
Silicone Cuff
Soft and flexible, conforms to the anatomy
Cuff Pilot Technology
An integrated, single-use cuff pressure indicator that constantly monitors cuff pressure
Available with a Pilot Balloon, a tactile cuff pressure indicator

A first generation, single-use airway with the added benefits of integrated cuff pressure monitoring and a silicone cuff. 1-3

Integrated Cuff Pilot Technology allows easy monitoring of cuff pressure throughout the procedure to account for changes due to temperature, nitrous oxide levels, and airway movement.
Also available with a Pilot Balloon, a tactile cuff pressure indicator, in lieu of Cuff Pilot Technology.
Designed for Clinicians and Patients by using silicone instead of PVC, which has shown greater elasticity for anatomical conformity and higher oropharyngeal seal pressures. 1,3-5

Phthalate free for ease of mind and patient safety.

Data Sheet

Portfolio Brochure

Item Number Mask Size PATIENT WEIGHT (KG) MAXIMUM CUFF
PRESSURE (CM H2O)
QTY/CASE
105200-000010 1 up to 5 60 10
105200-000015 1.5 5-10 60 10
105200-000020 2 10-20 60 10
105200-000025 2.5 20-30 60 10
105200-000030 3 30-50 60 10
105200-000040 4 50-70 60 10
105200-000050 5 70-100 60 10
105200-000060 6 over 100 60 10
Item Number Mask Size PATIENT WEIGHT (KG) MAXIMUM CUFF
PRESSURE (CM H2O)
QTY/CASE
105300-000010 1 up to 5 60 10
105300-000015 1.5 5-10 60 10
105300-000020 2 10-20 60 10
105300-000025 2.5 20-30 60 10
105300-000030 3 30-50 60 10
105300-000040 4 50-70 60 10
105300-000050 5 70-100 60 10
105300-000060 6 over 100 60 10
Item Number Mask Size PATIENT WEIGHT (KG) MAXIMUM CUFF
PRESSURE (CM H2O)
QTY/CASE
1F8010 1 up to 5 60 10
1F8015 1.5 5-10 60 10
1F8020 2 10-20 60 10
1F8025 2.5 20-30 60 10
1F8030 3 30-50 60 10
1F8040 4 50-70 60 10
1F8050 5 70-100 60 10
1F8060 6 over 100 60 10
*Plus Pack includes syringe, lubricant, and LMA Unique (Silicone Cuff) Airway
Item Number Mask Size PATIENT WEIGHT (KG) MAXIMUM CUFF
PRESSURE (CM H2O)
QTY/CASE
1FA010 1 up to 5 60 10
1FA015 1.5 5-10 60 10
1FA020 2 10-20 60 10
1FA025 2.5 20-30 60 10
1FA030 3 30-50 60 10
1FA040 4 50-70 60 10
1FA050 5 70-100 60 10
1FA060 6 over 100 60 10
*Plus Pack includes syringe, lubricant, and LMA Unique (Silicone Cuff) Airway

Sources:

  1. Eschertzhuber S, Brimacombe J, Hohlrieder M, Keller C. Anaesthesia. 2009;64(1):79-83.
  2. Martin DP, Bhalla T, Thung A, Tobias JD. Int J Pediatr Otorhinolaryngol. 2013;77(1):76-78. Research Sponsored by Teleflex Incorporated.
  3. Bell SF, Morris NG, Rao A, Wilkes AR, Goodwin N. Anaesthesia. 2012;67(12):1337-1342.
  4. Anand LK, Goel N, Singh M, Kapoor D. Acta anaesthesiologica Taiwanica. 2016;54(2):44-50.
  5. Van Zundert T, Brimacombe J. Anaesthesiol Intensive Ther. 2012;44(2):63-70. Research Sponsored by Teleflex Incorporated

LMA Unique EVO Airway

Intubation Capability
Compatible with endotracheal tubes sized up to 8.0 mm
Integral Bite Block
Designed to reduce the risk of dental damage
Silicone Cuff
Soft and flexible, and conforms to the anatomy
Cuff Pilot Technology
An integrated, single-use cuff pressure indicator that constantly monitors cuff pressure
Available with a Pilot Balloon, a tactile cuff pressure indicator

A first-generation, intubation-capable, single-use airway with the added benefit of a silicone cuff.

The LMA Unique EVO Airway from Teleflex is a fixed-curve, first generation laryngeal mask that is designed specifically to support fiber-scope-assisted direct intubation

Effective airway replacement during unforeseen difficult airway situations.

Versatility for clinicians with a full range of available sizes and both pilot balloon and Cuff Pilot Technology options.

Integrated bite block for patient protection and clinician ease.

Data Sheet

Portfolio Brochure

Item Number Mask Size PATIENT WEIGHT (KG) MAXIMUM CUFF
PRESSURE (CM H2O)
MAXIMUM
ENDOTRACHEAL TUBE ID (MM)
QTY/CASE
1D2010 1 up to 5 60 4.5 10
1D2015 1.5 5-10 60 4.5 10
1D2020 2 10-20 60 6.5 10
1D2025 2.5 20-30 60 6.5 10
1D2030 3 30-50 60 7.0 10
1D2040 4 50-70 60 7.5 10
1D2050 5 70-100 60 8.0 10
Item Number Mask Size PATIENT WEIGHT (KG) MAXIMUM CUFF
PRESSURE (CM H2O)
MAXIMUM
ENDOTRACHEAL TUBE ID (MM)
QTY/CASE
1D5010 1 up to 5 60 4.5 10
1D5015 1.5 5-10 60 4.5 10
1D5020 2 10-20 60 6.5 10
1D5025 2.5 20-30 60 6.5 10
1D5030 3 30-50 60 7.0 10
1D5040 4 50-70 60 7.5 10
1D5050 5 70-100 60 8.0 10

LMA Supreme Airway

Fixation Tab
Facilitates optimal positioning within the oropharynx, hypopharynx, and upper esophagus
Integral Bite Block
Designed to reduce the risk of dental damage
Elongated Cuff
Designed with a smoother profile to aid insertion
Gastric Access
Distal tip with gastric access designed to functionally separate the digestive and respiratory tracts
First Seal
Oropharyngeal seal
Curved Airway Tube
The elliptical and anatomically-shaped airway tube facilitates rapid insertion and is designed to minimize axial rotation once inserted

The innovative, single-use, second-generation LMA Airway

The LMA Supreme Airway from Teleflex is designed to increase efficacy and safety versus first-generation devices1.

Designed to limit risk of aspiration across a broad range of procedures.2-6

Gastric access up to 14 FR OG tube

Integrated bite block for patient protection and clinician ease.

Data Sheet

User Guide

Item
Number
MASK SIZE PATIENT WEIGHT (KG) MAXIMUM CUFF
PRESSURE (CM H2O)
MAXIMUM SIZE
OG TUBE (FR)
QTY/CASE
ALBF010SU 1 Up to 5 60 6 10
ALBF015SU 1.5 5 – 10 60 6 10
ALBF020SU 2 10 – 20 60 10 10
ALBF025SU 2.5 20 – 30 60 10 10
ALBF030SU 3 30 – 50 60 14 10
ALBF040SU 4 50 – 70 60 14 10
ALBF050SU 5 70 – 100 60 14 10

OG=Orogastric Tube

Sources:

  1. Cook T., Howes B. Contin Educ Anaesth Crit Care Pain. 2011;11(2):56-61.
  2. Abdi W, Amathieu R, Adhoum A, et al. Acta Anaesthesiol Scand. 2010;54(2):141-146.
  3. Yao WY, Li SY, Sng BL, Lim Y, Sia AT. Can J Anaesth. 2012;59(7):648-654.
  4. Belena JM, Gracia JL, Ayala JL, et al. J Clinl Anesth. 2011;23(6):456-460.
  5. Sharma V, Verghese C,† McKenna PJ. Br J Anaesth. 2010;105(2):228-232.
  6. Roiss M, Semrau M, Blanc I, Graefen M, Goetz AE, Reuter DA. Abstract and poster presentation at the Anesthesiology 2011 Annual Meeting (abstr. A1059)2011. Research Sponsored by Teleflex Incorporated.

LMA Gastro Airway

Endoscope Channel
Enables an endoscope to be passed through the device under vision
Adjustable Holder and Strap
Maintains the device in a neutral position during endoscope manipulation
Adjustable Holder and Strap
Maintains the device in a neutral position during endoscope manipulation
Integral Bite Block
Reduces the potential for damage to, or obstruction of, the airway tube or endoscope due to biting
Silicone Airway Tube and Cuff
Designed for smooth insertion and patient comfort
Cuff Pilot Technology
An integrated, single-use cuff pressure indicator that constantly monitors cuff pressure

Proactive airway management for endoscopy procedures

The LMA Gastro Airway with Cuff Pilot Technology is the first laryngeal mask specifically designed to enable clinicians to proactively manage their patients' airways while facilitating direct endoscopic access. With the airway in place, clinicians can monitor end-tidal CO2 for patient safety.

Endoscopic access up to 14mm OD via the integrated endoscope channel.

Reliable patient positioning is aided by the adjustable strap.

Clinical Study

Quick-Step Guide

Data Sheet

EGD Case Study

Item
Number
MASK SIZE PATIENT WEIGHT (KG) MAXIMUM INTRACUFF
PRESSURE (CM H20)
MAXIMUM ENDOSCOPE
SIZE (OD) (MM)
1E5030 3 30 – 50 60 14
1E5040 4 50 – 70 60 14
1E5050 5 70 – 100 60 14

*Cuff Pilot Technology recommendation for cuff pressure: green zone pressure range = 40 - 60 cm H20 for all sizes.

LMA Protector Airway

Intubation Capability
Compatible with endotracheal tubes sized up to 7.5 mm
Dual Gastric Access
Dual Gastric Access
Silicone Airway Tube with Dynamic Curve
First Seal Technology
Facilitates oropharyngeal seal
Second Seal Technology
Facilitates esophageal seal
Cuff Pilot Technology
An integrated, single-use cuff pressure indicator that constantly monitors cuff pressure

The most advanced second-generation airway from Teleflex.

The LMA Protector Airway with Cuff Pilot Technology is the only laryngeal mask that combines a pharyngeal chamber and dual gastric drainage channels, designed specifically to channel gastric content away from the airway.

Intubation capable for unforeseen difficult airway situtaions

100% silicone airway and cuff designed for enhanced flexibility and patient safety.

Instructional Video

Data Sheet

Quick-Step Guide

Brochure

Item
Number
MASK SIZE PATIENT WEIGHT (KG) MAXIMUM INTRACUFF
PRESSURE (CM H20)
MAXIMUM ENDOSCOPE
ETT ID (MM)
LARGEST SIZE
OG TUBE (FR)
192030 3 30 – 50 60 6.5 16
192040 4 50 – 70 60 7.5 18
192050 5 70 – 100 60 7.5 18

LMA Fastrach Airway System

Connector
Removable 15mm Connector
Pilot Balloon
Wire-Reinforced ETT
Developed specifically for use with the LMA Fastrach Airway
Insertion Handle
Designed for single-handled insertion from any position, eliminates the need for placing fingers in the patient's mouth
Soft, Bevel Tip
Designed for atraumatic passage through vocal cords
Soft, Inflatable Cuff
Designed to adapt to the contour of the hypopharynx
Epiglottic Elevating Bar
Designed to protect and elevate the epiglottis during ETT insertion
136070_LMA_Fastrach_ETT_Stabilizer_Rod_side_separated.jpg

A first-generation, single-use airway for Can't Intubate, Can't Ventilate (CICV) situations.

The LMA Fastrach Airway System is a ventilating and intubating LMA Airway that facilitates continuous ventilation and intubation in CICV situations. This device is designed for patients with an immediate need of an airway due to failed tracheal intubation or for whom tracheal intubation is not an option.

Designed as a guide for blind intubation of the trachea to allow continuous ventilation between intubation attempts.

One handed insertion, adjustment facilitated by the rigid handle.

All-in-one solution when you order the LMA Fastrach Mask, Endotracheal Tube (ETT), and Stabilizer Rod.

Insertion & Manuevers Guide

Item
Number
Description PATIENT WEIGHT (KG) MAXIMUM INTRACUFF
PRESSURE (CM H20)
QTY/CASE
135130 LMA Fastrach Single-Use Mask, Size 3 30 – 50 60 10
135140 LMA Fastrach Single-Use Mask, Size 4 50 – 70 60 10
135150 LMA Fastrach Single-Use Mask, Size 5 70 – 100 60 10
Item
Number
Description ETT SIZE (I.D.) CUFF
DIAMETER (MM)
QTY/CASE
136060 LMA Fastrach Single-Use Endotracheal Tube (with Stabilizer Rod) - Size 6 6.0 22 10
136065 LMA Fastrach Single-Use Endotracheal Tube (with Stabilizer Rod) - Size 6.5 6.5 23 10
136070 LMA Fastrach Single-Use Endotracheal Tube (with Stabilizer Rod) - Size 7 7.0 23 10
136075 LMA Fastrach Single-Use Endotracheal Tube (with Stabilizer Rod) - Size 7.5 7.5 24 10
136080 LMA Fastrach Single-Use Endotracheal Tube (with Stabilizer Rod) - Size 8 8.0 24 10

All LMA Fastrach Single-Use Mask sizes are compatible with all LMA Fastrach Single-Use ETT sizes.

LMA Flexible Airways

Connector
Standard 15 mm Connector
Reinforced Airway Tube
Aperture Bars
Deisgned to prevent the blockage of airflow by the epiglottis
Pilot Balloon
A tactile cuff pressure indicator

LMA Flexible Airway

LMA Flexible Precurved Airway

A first-generation, single-use airway designed with flexibility in mind

The LMA Flexible and LMA Flexible Precurved Airways are designed for positioning away from the surgical field without compromising seal integrity.

Wire reinforced airway tube designed to prevent kinking and provide flexibility.

Designed to protect patients by creating a barrier over the glottic opening and esophagus.

Data Sheet

Item
Number
Mask Size PATIENT WEIGHT (KG) MAXIMUM INTRACUFF
PRESSURE (CM H20)
115020 2 10-20 60
115025 2.5 20-30 60
115030 3 30-50 60
115040 4 50-70 60
115050 5 70-200 60
Item
Number
Mask Size PATIENT WEIGHT (KG) MAXIMUM INTRACUFF
PRESSURE (CM H20)
1B2020 2 10-20 60
1B2025 2.5 20-30 60
1B2030 3 30-50 60
1B2040 4 50-70 60
1B2050 5 70-200 60
Item
Number
Mask Size PATIENT WEIGHT (KG) MAXIMUM INTRACUFF
PRESSURE (CM H20)
1B5020 2 10-20 60
1B5025 2.5 20-30 60
1B5030 3 30-50 60
1B5040 4 50-70 60
1B5050 5 70-200 60

Cuff Pilot Technology

Cuff Pilot Technology

A integreated cuff pressure indicator

Cuff Pilot Technology is an integrated, single-use cuff pressure indicator that constantly monitors cuff pressure, detecting changes resulting from fluctuations in temperature, nitrous oxide levels, and movements within the airway.

Better outcomes:
Cuff Pilot Technology was developed to support clinicians in avoiding the known risks of cuff hyperinflation like sore throat and increased risk of aspiration due to leakage.1-3

Simple to use:
Provides at-a-glance manometry of cuff pressure levels througout the entire procedure.

Supports a reliable seal:
Designed to help clinicians maintain the optimal intracuff pressure of 40-60 cm H2O required to achieve a reliable oropharyngeal seal.

Reduced risk of airway complication:
Allows for monitoring intracuff pressure to ensure it does not exceed 60 cm H2O - a strategy shown to reduce airway complications by up to 70%.4

Clinical Study

Brochure

Bibliography

Sources:

  1. Van Zundert T, Brimacombe J. Anaesthesiol Intensive Ther. 2012;44(2):63-70. Research Sponsored by Teleflex Incorporated.
  2. Burgard G, Mollhoff T, Prien T. J Clin Anesth. 1996;8(3):198-201.
  3. Wong D, Tam A, Mehta V, Raveendran R, Riad W, Chung F. Can J Anesth/J Can Anesth (2013) 60:1197-1203.
  4. Seet E, Yousaf F, Gupta S, Subramanyam R, Wong DT, Chung F. Anesthesiology. 2010;112(3):652-657. Research Sponsored by Teleflex Incorporated.
Rx Only. Teleflex, the Teleflex logo, Cuff Pilot, Gastro, LMA, LMA Protector, LMA Supreme, LMA Unique, and Unique EVO are trademarks or registered trademarks of Teleflex Incorporated or its affiliates. Information in this material is not a substitute for the product Instructions for Use. Not all products may be available in all countries. Please contact your local representative. MC-005133 Rev 3